ALMAEER
Office 301, MAJ Building
6 Al Haylah St., Al Nahyan
Abu Dhabi, UAE
PO Box 48227 AUH
Phone: +971 2 666 1239
admin@almaeer.com
Jacking System Verification Services for ADNOC (UAE)
Client: ADNOC
Provided services: Jacking System Verification
Duration: 2023-2026
Location: UAE
In 2023 ALMAEER was awarded with a 3-year contract with ADNOC. We provide Jacking System Verification Services for the 77 ADNOC Offshore Jack-up Rigs & Barges.
Jacking Systems are identified by ADNOC as a critical equipment system on offshore jack-up units. To minimize the risks of failure of the physical assets, ADNOC has directed ALMAEER to carry out independent verification of the jacking systems on all ADNOC contracted jack up rigs and jack up barges.
Jacking System Assurance Audits covering:
Rig condition survey and CAT IV Inspection for ERIELL (Uzbekistan)
Client: EREIELL GROUP
Provided services: Rig inspection services
Duration: 2024
Location: Uzbekistan
Almaeer has been awarded with a contract to provide Rig inspection services for ERIELL GROUP on their land rig ZJ-70 based in Uzbekistan.
This Project composes of two phases: Phase 1 being the Rig Condition Survey, and Phase 2 the CAT IV Inspection (including NDT Inspection).
Audit Objectives for this project shall encompass the following:
Acceptance audit of the mast raising equipment (UAE)
Client: Ocean Oil Services ( HILONG HOLDING LIMITED)
Provided services: Acceptance audit of the mast raising equipment
Duration: 2023-2023
Location: Sharjah, UAE
OCEAN OIL SERVICES (a wholly owned subsidiary of ”HILONG HOLDING LIMITED”) requested Almaeer to perform an acceptance audit of the mast raising equipment on their rig HL30, located in Sharjah field.
The scope of work included the following::
Pre-hire audit for land rig (Poland)
Client: U.DRILL LLC
Provided services: Pre-hire audit
Duration: 2023-2023
Location: Poland
U.DRILL LLC has requested ALMAEER to carry out a rig pre-hire audit on one of their clients’ land rigs BK-68 in Eastern Europe.
Inspection was conducted according the following audit objectives:
Shipyard refurbishment project evaluation audit (Bahrain)
Client: Dynamic Drilling and Services
Provided services: Provide shipyard refurbishment project evaluation audit
Duration: 2023-2023
Location: Bahrain
Dynamic Drilling and Services PLC has requested ALMAEER to provide Shipyard refurbishment project evaluation audit for their rig Divine Driller (Marathon Le Tourneau Class 116-C) in the ASRY shipyard in Bahrain.
The rig inspection audit included the following requirements:
Pre-hire and Commissioning Survey for Almansoori / Taq Taq Operating Company (Iraq)
Client: Almansoori/Taq Taq Operating Company
Provided services: Rig pre-hire audit and electrical camp inspection for the land rig
Duration: 2023-2023
Location: Iraq
ALMAEER has been conducted pre-hire audit and electrical camp inspection for the land rig HONESTAR HS-036.
The scope of work included the following:
Acceptance Mechanical Audit on the Rig for Selective Marine Services (UAE)
Client: Selective Marin Services
Provided services: Specific Acceptance Mechanical audit covering ANDOC compliance standards
Duration: 2020-2020
Location: China
ALMAEER carried out specific ADNOC acceptance audit for SMS ESSA Le Tourneau S 116E at COSCO shipyard Dalian China to facilitate smooth acceptance by ADNOC covering all ADNOC compliance standards.
The survey included the following Mechanical requirements:
Rig condition surveys for the National Oilwells Drilling & Workover Company (Libya)
Client: National Oilwells Drilling & Workover Company / ALMANSOORI
Provided services:
SAPI RP 4G, 7L, 8B Cat III,
API RP 4G Cat IV
Duration: 2022-2022
Location: Libya
In 2022 ALMAEER was chosen by National Oilwells Drilling & Workover Company for the follow services for their rigs and units in Libya:
Commissioning and rig condition surveys for the Damson Energy (UAE)
Client: Damson Energy / ALMANSOORI
Provided services: Rig API 8B/7L/4G CAT III Refurbishment Acceptance
Duration: 2021-2021
Location: UAE
Damson Energy has directed ALMAEER to perform commissioning and rig condition surveys for their rigs and units located in UAE.
ALMAEER performed Reactivation Commissioning and API RP 4G, 7L, 8B work scopes to ADNOC acceptance requirements and Condition Survey to applicable standards API RP 4G, 7L, 8B work scopes to ADNOC acceptance requirements.
Full condition inspection for Urja Bharat Pte (UAE)
Client: Urja Bharat Pte / ALMANSOORI
Provided services: Full condition acceptance audit
Duration: 2022-2022
Location: UAE
ALMAEER carried out full condition acceptance for land rig AD 125 to prepare them for operations with ADNOC Onshore. All applicable ADNOC standards were utilized and audits done accordingly.
Objectives for this audit were:
If you have an inquiry please contact us.
Office 301, MAJ Building
6 Al Haylah St., Al Nahyan
Abu Dhabi, UAE
PO Box 48227 AUH
Phone: +971 2 666 1239
admin@almaeer.com